    Perhaps someone has had this happen to them ? My PO 2500 was serviced 2 years ago and not worn more than a handful of times since . Not had a knock or drop .
    The second hand sticks at 34 . A good shake gets it past but sticks again the same place . This is after a decent hand wind or wearing it .
    I know it’s the devil’s job to diagnose a fault without it in front you ! Service was by James who was on here but I can’t message as this is turned off for him

  2. #2
    Master bazza.'s Avatar
    Join Date
    Jul 2009
    Location
    North Warwickshire
    Posts
    3,224
    Is the hand maybe catching the hour marker ?

  3. #3
    Master
    Join Date
    Sep 2012
    Location
    portsmouth
    Posts
    1,349
    I’ve tried different hand positions , doesn’t make it better or worse - can’t see it hitting the crystal either . Just odd !

  4. #4
    Master
    Join Date
    Dec 2010
    Location
    NW Leics
    Posts
    8,231
    Yes but the hour baton at the 7 o'clock position - seems to me to be the most likely suspect. It may not have the motivation but it does have the means and the opportunity.

  5. #5
    Master
    Join Date
    Sep 2012
    Location
    portsmouth
    Posts
    1,349
    I’ll get the loupe out - I think it’s well clear but worth a look